Fluke Clamp Meter, 999.9 A. 600 VAC, 1000 VDC Electrical Rating, 60 kOhm Resistance, 500 Hz Frequency, 34 mm Jaw, Removable Wireless Display, 2% +/-5 Digits at 999.9 A, 3% +/-5 Digits at 2500 A AC Current Accuracy, 1.5% +/-5 Digits at 1000 VAC, 1% +/-5 Digits at 1000 VDC Voltage Accuracy, Safety Rating: CAT IV 600 VAC/CAT III 1000 VAC, -10 to 50 deg C Operating, 10.9 in L x 3.46 in W x 1.69 in H Dimensions, Hard Plastic
EN 61326-1:2006|EN 61326-2-2:2006|ETSI EN 300 328 V1.7.1:2006|ETSI EN 300 489 V1.8.1:2008|FCC Part 15 SubPart C Section 15.207|FCC Part 15 SubPart C Section 15.209|FCC Part 15 SubPart C Section 15.249|FCCID: T68-F381RSS-210 IC: 6627A-F381|ANSI/ISA S82.02.01:2004|CAN/CSA C22.2 File No. 61010-1-04|IEC/EN 61010-1:2001 to 1000 VAC/VDC CAT III/600 VAC/VDC CAT IV|ECCN: 3A992|PROP65: This product is in compliance with Prop65, it is not known to contain any chemicals associated with this regulation
Wireless technology allows the display to be carried up to 30 ft away from the point of measurement for added flexibility without interference with measurement accuracy|The removable magnetic display can be conveniently mounted where it is easily seen|IFlex flexible current probe expands the measurement range to 2500 A AC|CAT IV 600 VAC/VDC, CAT III 1000 VAC/VDC|Integrated low pass filter and state-of the art signal processing allows for use in noisy electrical environments while providing stable readings|Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it|Ergonomic design fits in your hand and can be used while wearing protective equipment|Radio transmitter automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement|Soft carrying case|Accuracy - 2% +/-5 digits dc current/1.5% +/-5 digits (20 to 500 Hz) AC voltage/1% +/-5 digits dc voltage/ 1% +/-5 digits resistance|Resolution - 0.1 A AC current via jaw/0.1 A (</=600 a)/1 A (</=2500 a) AC current via flexible current probe/0.1 a DC current/0.1 VAC voltage/0.1 VDC voltage/0.1 Ohm/1 Ohm/10 Ohm resistance|2000 m operating altitude, 12000 m storage altitude|7.5 mm flexible current probe diameter|1.8 m flexible current probe cable length (head to electronics connector)|Add 0.1 x specified accuracy for each deg C above 28 deg C or below 18 deg C temperature coefficients|3 at 500 A, 2.5 at 600 A, 1.42 at 1000 A, add 2% for C.F, >2 AC current via jaw/3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2% for C.F, >2 2 AC current via flexible current probe crest factor (50/60 Hz)|<=30 Ohm measure continuity|100 ms measure inrush|Range 5 to 500 Hz frequency via jaw and flexible current probe, 600 Ohm/6 kOhm/60 kOhm resistance, 2% +/-5 digit (10 to 100 Hz), 5% +/-5 digit (100 to 500 Hz) via jaw, 3% +/-5 digit via flexible current probe AC current accuracy, 1.5% +/-5 digit (20 to 500 Hz) AC voltage, 1% +/-5 digit DC voltage accuracy
AC Current Accuracy
2% +/-5 Digits at 999.9 A, 3% +/-5 Digits at 2500 A
Dimensions
10.9 in L x 3.46 in W x 1.69 in H
Display Type
Removable Wireless
Electrical Ratings
999.9 A. 600 VAC, 1000 VDC
Frequency Rating
500
Jaw Capacity
34
Material
Hard Plastic
Operating Temperature
-10 to 50
Resistance
60
Safety Rating
CAT IV 600 VAC/CAT III 1000 VAC
Voltage Accuracy
1.5% +/-5 Digits at 1000 VAC, 1% +/-5 Digits at 1000 VDC
Brand
Fluke
Manufacturer
Fluke